Parts you can order now
|
Sensors |
Description |
VT205 Series

Sensor . Shown located in process line. |
Lab Beaker, Process or OEM Viscometer with Temperature Sensor
5” stem, anodized aluminium body,
¼” NPT extension thread,
10 ft. lead.
Temperature
Range: 0 to 190
c
Accuracy ±0.5c, Resolution ±0.1c
Viscosity
Model :
Range : Accuracy : Resolution
VT205-41 : 2 to 40cp ± 2% FS ± 0.1cp
VT205-12 : 5 to 100cp ± 2% FS ± 0.1cp
VT205-42 : 20 to 400cp ± 2% FS ± 1cp
VT205-13 : 50 to 1,000cp ± 2% FS ± 1cp
Requires series 1 electronics [C100, B1ac, B112, B1dc]
Mates to XC1-xxx extension cable with junction box.
|
VT225 Series

Lab use. Process tank use.
|
Same as VT205 plus higher accuracy temperature sensor
Temperature Range: 0 to 190 c
Accuracy ±0.1c, Resolution ±0.1c
Viscosity
Model : Range : Accuracy : Resolution
VT225-41: 2 to 40cp ± 2% FS ± 0.1cp
VT225-12 : 5 to 100cp ± 2% FS ± 0.1cp
VT225-42 : 20 to 400cp ± 2% FS ± 1cp
VT225-13 : 50 to 1,000cp ± 2% FS ± 1cp
Requires series 2 electronics [C200, B2ac, B212, B2dc]
Mates to XC2-xxx extension cable with junction box.
|
| VS205 Series

Application mountings are as shown above. |
Lab Beaker, Process or OEM Viscometer with Temperature Sensor
5” stem, 316ss body,
¼” NPT extension thread,
10 ft. lead.
Magnetic Detection
Temperature Range: 0 to 190 c
Accuracy ±0.5c, Resolution ±0.1c
Viscosity
Model : Range : Accuracy : Resolution
VS205-41 : 2 to 40cp ± 2% FS ± 0.1cp
VS205-12 : 5 to 100cp ± 2% FS ± 0.1cp
VS205-42 : 20 to 400cp ± 2% FS ± 1cp
VS205-13 : 50 to 1,000cp ± 2% FS ± 1cp
Requires series 1 electronics [C100, B1ac, B112, B1dc]
Mates to XC1-xxx extension cable with junction box.
|
| VS225 Series
Pictures of sensor and application mounting are as shown above. |
Same as VS205 plus higher accuracy temperature sensor
Temperature Range: 0 to 190 c
Accuracy ±0.1c, Resolution ±0.1c
Viscosity
Model : Range : Accuracy : Resolution
VS225-41 : 2 to 40cp ± 2% FS ± 0.1cp
VS225-12 : 5 to 100cp ± 2% FS ± 0.1cp
VS225-42 : 20 to 400cp ± 2% FS ± 1cp
VS225-13 : 50 to 1,000cp ± 2% FS ± 1cp
Requires series 2 electronics [C200, B2ac, B212, B2dc]
Mates to XC2-xxx extension cable with junction box.
|
|
VSH333 Series
NEW 
|
Process Viscometer with Temperature Sensor
Non Magnetic
Ratiometric Measurement.
3” stem, 316ss body,
10 ft [3m] cable with 6-pin locking connector
Temperature Range: 0 to 190 c
Accuracy ±0.1c, Resolution ±0.1c
Viscosity
Model : Range : Accuracy : Resolution
VSH333-41 : 2 to 40cp ± 2% FS ± 0.1cp
VSH333-12 : 5 to 100cp ± 2% FS ± 0.1cp
VSH333-42 : 20 to 400cp ± 2% FS ± 1cp
VSH333-13 : 50 to 1,000cp ± 2% FS ± 1cp
Requires series 3 electronics [C300, B3ac, B312, B3dc]
Mates to XC3-xxx extension cable with pre-amp
|
Electronics |
Description |
C100 Electronics

|
Panel or Bench Top Electronics
Enclosure with dual displays
RS-232 interface
90-240Vac power
1,000 event data logging, monitoring and advisory alarm software
4-20ma sourced outputs (<=450 ohm loop resistance).
Interface software
Operates Vx205 sensors [VS205 or VT205]
Mates to XC1 cable.
|
C200 Electronics
NEW
|
Same as C100 - plus
Front panel LED display of measurement and alarm state.
5V TTL level alarm output on back
Locking 6 pin sensor connect.
Operates Vx225 sensors [VT225 or VS225]
Mates to XC2 extension cable for runs greater than 10ft/3m
|
C300 Electronics
NEW
|
Same as C200 - plus
Software for ratio-metric operation of 300 series
Sensors [VSH333]
Mates to XC3 extension cable for runs greater than 10ft/3m
|
OEM Electronics
 |
OEM Electronics with resident firmware and operator software.
Full functionality without local displays or enclosure.
RS-232 interface with 1,000 event monitoring and alarm software. Barrier strip for either 0 to 4Vdc or 4 to 20ma analog outputs.
Bx12: Input power ±12Vdc at 300ma
Bxdc: Input power +9 to +36 Vdc at 300ma
Bxac: Input power 90-240Vac, 50-60Hz Price is
Where “x” is 1, 2, or 3 series, e.g. B3ac for VSH333, B2ac for VS225
|
Viscosity Measuring System |
Description |
TSV300 System
NEW 
|
Temperature Stabilised Viscometer
Unique closed loop temperature stabilisation of a small slip stream eliminating the effects of process or ambient temperature changes.
Set point temperature :
10 degrees C above ambient to 100 degC.
Interface : RS232, 4-20ma
Supplied software with control and data logging.
115Vac mains powered.
T300 electronic control system mounts up to 328 ft [100m] from system.
Benefit.
The TSV300 has the advantage of giving less errors than systems which measure at the wrong (or unknown) temperatures, and then correct the results using a mathematical model. We can supply mathematical models to correct for temperature changes. We can also supply a mathematical analysis f the errors.
|
Support to help you with this product
|
FAQ |
To be added
|
Downloads |
Data Sheets
Application notes
Presentations
.
|
On Demand Sample Testing |
see Testing : Inks, Paints, Foods, Water based, Organic based
|
On Demand Process Measurements |
see In Process
|